Want To Learn How To Charge Your Home Air conditioning System To Have It Blowing Ice Cold Similar New Again?

Before we begin allow me beginning off past maxim your air conditioner should never exist low on refrigerant.  Freon (R-22) and Puron (R-410a)  systems are sealed circuits and then they should always have the same amount of refrigerant that they did when they were installed. The only reason you should ever find your Air-conditioning low on refrigerant is if your air conditioner has developed a leak. Below nosotros are going to simplify checking and charging your Air conditioning system all while leaving out  the AC mumbo jumbo you don't care near.

3 Reasons Your Ac Develops A Leak

Lack Of Maintenance Or Fail

Manufacturer Defect

Age Of Organization

Signs Your AC Is Low On Freon Or Puron

Not Blowing Cold Air

Long Run Time

Can Achieve Ready Temperature

Air-conditioning Lines Freezing

Checking Freon Or Puron Simplified

In social club to cheque the refrigerant levels on your air conditioner you volition need refrigerant gauges. If you lot do non own a pair or know someone that will lend y'all theirs I have a special link to contractor priced gauges here.

One time you accept your gauges plow your air conditioner on absurd way and so attach the blue hose to the larger of the 2 copper pipes on the outdoor unit.

Read the label on your outdoor Ac unit to determine what kind of refrigerant your system takes. Air conditioners installed 2009 and before are typically Freon (R-22) and those installed afterward are most probable Puron (R-410a).

If your air conditioner runs on R-22 the desired PSI is 75.

If your air conditioner runs on R-410a the desired PSI is 125.

If your system is more than five PSI below the desired number your Ac desperately needs refrigerant. In social club to handle refrigerant or purchase past law you are supposed to have an EPA license. For those  DIY home owners and handy folks R-22 and R-410a are available through Amazon. R-22 is being phased out past the EPA therefore the price of it is extremely loftier so I take provided a links for an  R-22 alternative 407c as well as the real stuff.

Charging Refrigerant

With blue hose attached to the copper piping adhere the yellow hose to your refrigerant canister.

Open the valve on the refrigerant canister all the way. For R-22 and 407c do this right side upwards. For R-410a practise this upside downward as well as accuse upside downward.

plow the handle on your gauges  to allow refrigerant to accuse in 10 second increments with a 1 minute pause in between to let refrigerant to bike through air conditioner.

For Ways To Preclude A Freon Leak

Preventing A Freon Leak